Hello,
I´m currently working with the impedance converter AD5933. I´m having some problems to compare the data that I get from the AD5933 with a LRC meter. I start my measurement by configurating my frequency start, the increment and number of increments. In my case I´m running frequency sweep with a range from 1kHz to 100kHz.
I started by calculating the gain factor with a know impedance, and then I start my measurement. I get the real and the imaginary data from the register specify at the datasheet, then I calculate the magnitude and the impedance also with the formulas that are in the datasheet.
However when I want to compare the impedance that I get with a LCR meter, the data is different and I don´t really know why. I have done some examples as explained in the datasheet but I don´t know if there is any detail that I´m missing.
To double check my data I also got the resistive and reactive from my impedance convertor and the phase (as specify in the datasheet) but I have not yet have any success.
Have someone had something similar?
Thanks Daphne