64 bit system serial device: /dev/ttyUSB0 with 2400 baud Port Modus 8N1 wakeup(): Sende Aufwachsequenz Pause 350 ms Port Modus 8E1 snd_ud_frame(): Setze Datenrahmen: [00] [68][04][04][68][53][FE][50][00][A1][16] mbus_bytes_received: 1 [E5] ACK empfangen req_ud2(): Sende Anfrage Daten Klasse 2 [10][5B][FE][59][16] mbus_bytes_received: 1 [68] mbus_bytes_received: 4 [94] [94] [68] [08] mbus_bytes_received: 3 [00] [72] [02] mbus_bytes_received: 4 [13] [49] [44] [93] mbus_bytes_received: 3 [15] [2F] [04] mbus_bytes_received: 4 [70] [00] [00] [00] mbus_bytes_received: 3 [0C] [06] [90] mbus_bytes_received: 4 [01] [04] [00] [8C] mbus_bytes_received: 3 [10] [06] [00] mbus_bytes_received: 4 [00] [00] [00] [8C] mbus_bytes_received: 3 [20] [13] [03] mbus_bytes_received: 4 [00] [00] [00] [0C] mbus_bytes_received: 4 [13] [60] [01] [13] mbus_bytes_received: 3 [01] [0C] [2B] mbus_bytes_received: 4 [06] [06] [00] [00] mbus_bytes_received: 3 [0B] [3B] [12] mbus_bytes_received: 4 [00] [00] [0A] [5A] mbus_bytes_received: 3 [68] [06] [0A] mbus_bytes_received: 4 [5E] [31] [02] [0A] mbus_bytes_received: 3 [62] [36] [04] mbus_bytes_received: 4 [0A] [27] [01] [17] mbus_bytes_received: 3 [04] [6D] [0B] mbus_bytes_received: 4 [10] [D7] [2C] [4C] mbus_bytes_received: 3 [06] [43] [80] mbus_bytes_received: 4 [03] [00] [4C] [13] mbus_bytes_received: 3 [22] [09] [07] mbus_bytes_received: 4 [01] [CC] [10] [06] mbus_bytes_received: 3 [00] [00] [00] mbus_bytes_received: 4 [00] [CC] [20] [13] mbus_bytes_received: 3 [03] [00] [00] mbus_bytes_received: 4 [00] [42] [6C] [DF] mbus_bytes_received: 3 [25] [42] [EC] mbus_bytes_received: 4 [7E] [FF] [25] [CC] mbus_bytes_received: 3 [01] [06] [44] mbus_bytes_received: 4 [33] [03] [00] [CC] mbus_bytes_received: 3 [01] [13] [76] mbus_bytes_received: 4 [06] [93] [00] [CC] mbus_bytes_received: 3 [11] [06] [00] mbus_bytes_received: 4 [00] [00] [00] [CC] mbus_bytes_received: 3 [21] [13] [02] mbus_bytes_received: 4 [00] [00] [00] [C2] mbus_bytes_received: 3 [01] [6C] [BF] mbus_bytes_received: 4 [2C] [C2] [01] [EC] mbus_bytes_received: 3 [7E] [DF] [2C] mbus_bytes_received: 2 [0F] [16] Empfang: 154 bytes Data: {0x68, 0x94, 0x94, 0x68, 0x08, 0x00, 0x72, 0x02, 0x13, 0x49, 0x44, 0x93, 0x15, 0x2F, 0x04, 0x70, 0x00, 0x00, 0x00, 0x0C, 0x06, 0x90, 0x01, 0x04, 0x00, 0x8C, 0x10, 0x06, 0x00, 0x00, 0x00, 0x00, 0x8C, 0x20, 0x13, 0x03, 0x00, 0x00, 0x00, 0x0C, 0x13, 0x60, 0x01, 0x13, 0x01, 0x0C, 0x2B, 0x06, 0x06, 0x00, 0x00, 0x0B, 0x3B, 0x12, 0x00, 0x00, 0x0A, 0x5A, 0x68, 0x06, 0x0A, 0x5E, 0x31, 0x02, 0x0A, 0x62, 0x36, 0x04, 0x0A, 0x27, 0x01, 0x17, 0x04, 0x6D, 0x0B, 0x10, 0xD7, 0x2C, 0x4C, 0x06, 0x43, 0x80, 0x03, 0x00, 0x4C, 0x13, 0x22, 0x09, 0x07, 0x01, 0xCC, 0x10, 0x06, 0x00, 0x00, 0x00, 0x00, 0xCC, 0x20, 0x13, 0x03, 0x00, 0x00, 0x00, 0x42, 0x6C, 0xDF, 0x25, 0x42, 0xEC, 0x7E, 0xFF, 0x25, 0xCC, 0x01, 0x06, 0x44, 0x33, 0x03, 0x00, 0xCC, 0x01, 0x13, 0x76, 0x06, 0x93, 0x00, 0xCC, 0x11, 0x06, 0x00, 0x00, 0x00, 0x00, 0xCC, 0x21, 0x13, 0x02, 0x00, 0x00, 0x00, 0xC2, 0x01, 0x6C, 0xBF, 0x2C, 0xC2, 0x01, 0xEC, 0x7E, 0xDF, 0x2C, 0x0F, 0x16, } Length: 148 Checksum OK C-Field: 0x08 Primary Adress: 0x00 Ci-Field: 0x72 variable Antwort, fixed header 12 Bytes DIF 0C VIF 06 function_field: 00 data_length: 4 data_field: 0C unit: 06 data bytes: 90 01 04 00 Instantaneous value Energy (kWh) mbus_parse_data_field: DIF 0x0C was decoded using 8 digit BCD result: 40190 factor 1.000000 n: 3 neg 0 DIF 8C DIFE 10 VIF 06 function_field: 00 data_length: 4 data_field: 0C unit: 06 data bytes: 00 00 00 00 Instantaneous value Energy (kWh) mbus_parse_data_field: DIF 0x8C was decoded using 8 digit BCD result: 0 factor 1.000000 n: 3 neg 0 DIF 8C DIFE 20 VIF 13 function_field: 00 data_length: 4 data_field: 0C unit: 13 data bytes: 03 00 00 00 Instantaneous value Volume (m m^3) mbus_parse_data_field: DIF 0x8C was decoded using 8 digit BCD result: 3 factor 0.001000 DIF 0C VIF 13 function_field: 00 data_length: 4 data_field: 0C unit: 13 data bytes: 60 01 13 01 Instantaneous value Volume (m m^3) mbus_parse_data_field: DIF 0x0C was decoded using 8 digit BCD result: 1130160 factor 0.001000 DIF 0C VIF 2B function_field: 00 data_length: 4 data_field: 0C unit: 2B data bytes: 06 06 00 00 Instantaneous value Power (W) mbus_parse_data_field: DIF 0x0C was decoded using 8 digit BCD result: 606 factor 1.000000 DIF 0B VIF 3B function_field: 00 data_length: 3 data_field: 0B unit: 3B data bytes: 12 00 00 Instantaneous value Volume flow (m m^3/h) mbus_parse_data_field: DIF 0x0B was decoded using 6 digit BCD result: 12 factor 0.001000 DIF 0A VIF 5A function_field: 00 data_length: 2 data_field: 0A unit: 5A data bytes: 68 06 Instantaneous value Flow temperature (1e-1 deg C) mbus_parse_data_field: DIF 0x0A was decoded using 4 digit BCD result: 668 factor 0.100000 DIF 0A VIF 5E function_field: 00 data_length: 2 data_field: 0A unit: 5E data bytes: 31 02 Instantaneous value Return temperature (1e-1 deg C) mbus_parse_data_field: DIF 0x0A was decoded using 4 digit BCD result: 231 factor 0.100000 DIF 0A VIF 62 function_field: 00 data_length: 2 data_field: 0A unit: 62 data bytes: 36 04 Instantaneous value Temperature Difference (1e-1 deg C) mbus_parse_data_field: DIF 0x0A was decoded using 4 digit BCD result: 436 factor 0.100000 DIF 0A VIF 27 function_field: 00 data_length: 2 data_field: 0A unit: 27 data bytes: 01 17 Instantaneous value Operating time (days) mbus_parse_data_field: DIF 0x0A was decoded using 4 digit BCD result: 1701 DIF 04 VIF 6D function_field: 00 data_length: 4 data_field: 04 unit: 6D data bytes: 0B 10 D7 2C Instantaneous value Time Point (time & date) DIF 4C VIF 06 function_field: 00 data_length: 4 data_field: 0C unit: 06 data bytes: 43 80 03 00 Instantaneous value Energy (kWh) mbus_parse_data_field: DIF 0x4C was decoded using 8 digit BCD result: 38043 factor 1.000000 n: 3 neg 0 DIF 4C VIF 13 function_field: 00 data_length: 4 data_field: 0C unit: 13 data bytes: 22 09 07 01 Instantaneous value Volume (m m^3) mbus_parse_data_field: DIF 0x4C was decoded using 8 digit BCD result: 1070922 factor 0.001000 DIF CC DIFE 10 VIF 06 function_field: 00 data_length: 4 data_field: 0C unit: 06 data bytes: 00 00 00 00 Instantaneous value Energy (kWh) mbus_parse_data_field: DIF 0xCC was decoded using 8 digit BCD result: 0 factor 1.000000 n: 3 neg 0 DIF CC DIFE 20 VIF 13 function_field: 00 data_length: 4 data_field: 0C unit: 13 data bytes: 03 00 00 00 Instantaneous value Volume (m m^3) mbus_parse_data_field: DIF 0xCC was decoded using 8 digit BCD result: 3 factor 0.001000 DIF 42 VIF 6C function_field: 00 data_length: 2 data_field: 02 unit: 6C data bytes: DF 25 Instantaneous value Time Point (date) DIF 42 VIF EC VIFE 7E function_field: 00 data_length: 2 data_field: 02 unit: 6C data bytes: FF 25 Instantaneous value Time Point (date) DIF CC DIFE 01 VIF 06 function_field: 00 data_length: 4 data_field: 0C unit: 06 data bytes: 44 33 03 00 Instantaneous value Energy (kWh) mbus_parse_data_field: DIF 0xCC was decoded using 8 digit BCD result: 33344 factor 1.000000 n: 3 neg 0 DIF CC DIFE 01 VIF 13 function_field: 00 data_length: 4 data_field: 0C unit: 13 data bytes: 76 06 93 00 Instantaneous value Volume (m m^3) mbus_parse_data_field: DIF 0xCC was decoded using 8 digit BCD result: 930676 factor 0.001000 DIF CC DIFE 11 VIF 06 function_field: 00 data_length: 4 data_field: 0C unit: 06 data bytes: 00 00 00 00 Instantaneous value Energy (kWh) mbus_parse_data_field: DIF 0xCC was decoded using 8 digit BCD result: 0 factor 1.000000 n: 3 neg 0 DIF CC DIFE 21 VIF 13 function_field: 00 data_length: 4 data_field: 0C unit: 13 data bytes: 02 00 00 00 Instantaneous value Volume (m m^3) mbus_parse_data_field: DIF 0xCC was decoded using 8 digit BCD result: 2 factor 0.001000 DIF C2 DIFE 01 VIF 6C function_field: 00 data_length: 2 data_field: 02 unit: 6C data bytes: BF 2C Instantaneous value Time Point (date) DIF C2 DIFE 01 VIF EC VIFE 7E function_field: 00 data_length: 2 data_field: 02 unit: 6C data bytes: DF 2C Instantaneous value Time Point (date) ------------------------------------------------- primary_address: 0x00 customer_number: 44491302 manufacturer: ELS generation: 47 medium: 4 = Wärme reading_counter: 112 error_code: 0 signature: 0 fabrication_number: 0 energy: 0 kWh volume: 2 l power: 606 W flow: 12 l/h supply_temp: 66.8 °C return_temp: 23.1 °C temp_difference: 43.60 K date: 31.12.2022 time: 00:00:00 operating_time: 1701 d firmware_version: 0 software_version: 0 alarm_code: 0 -------------------------------------------------